top of page

When to Use Fire-Rated Cleats in Electrical Installations

  • Writer: Nasco Corp
    Nasco Corp
  • Sep 22
  • 3 min read

ree

Introduction: When to Use Fire-Rated Cleats Use fire-rated cleats in electrical installations where fire safety is critical, such as high-rise buildings, tunnels, hospitals, and industrial facilities with fire-resistant cables. These cleats maintain cable support during fires, complying with BS 5839 and IEC 61914, preventing collapse and ensuring circuit integrity for evacuation.

Understanding Fire-Rated Cleats

Fire-rated cleats secure cables under extreme heat, impact, and water, using halogen-free materials to limit flame spread. They are essential for life-safety systems, retaining cables per BS 5839 standards.

Key Applications

  • High-Risk Areas: Tunnels, stairwells, and escape routes.

  • Critical Infrastructure: Hospitals, data centers, and fire-fighting systems.

  • Industrial Settings: Chemical plants and offshore platforms.

Expert Insight: BS 5839 requires non-combustible supports that match cable fire performance, reducing risks by 30% in emergencies.

Real-Life Example: In a 2024 London high-rise fire, fire-rated cleats from CMP Products maintained emergency lighting, aiding evacuation and saving lives.

Top Features of Electrical Cable Cleats for Industrial Use

Electrical cable cleats for industrial use prioritize durability and compliance.

Feature

Benefit

Example

Corrosion Resistance

Withstands harsh environments

316L stainless steel

Short-Circuit Rating

Handles 193 kA faults

IEC 61914-tested

Flame Retardancy

Limits fire spread

UL94 V0 polymers

Easy Installation

Reduces labor time

Tool-free designs

Expert Insight: Panduit's ANSYS simulations ensure cleats endure industrial stresses, boosting reliability by 25%.

Statistics: 57% of HV failures stem from poor support; industrial cleats cut this risk significantly. Read this also...Top Features of Electrical Cable Cleats for Industrial Use

How to Select Cable Support Cleats for High-Voltage Applications

Selecting cable support cleats for high-voltage applications involves assessing cable type, environment, and fault levels.

  1. Evaluate Cable Configuration: Trefoil for three-phase; single for spaced runs.

  2. Check Short-Circuit Rating: Ensure 100+ kA tolerance per IEC 61914.

  3. Consider Environment: Stainless steel for corrosion; polymers for fire safety.

  4. Verify Spacing: 0.3-0.6m intervals for stability.

Real-Life Example: A substation project used Ellis Emperor cleats, withstanding 193 kA faults and reducing downtime by 20%. Read this also...How to Select Cable Support Cleats for High-Voltage Applications

How to Install UV-Resistant Outdoor Cable Cleats Properly

For outdoor installations, UV-resistant cleats prevent degradation from sunlight and weather.

Installation Steps

  • Site Prep: Clean trays; assess UV exposure.

  • Measure Spacing: 0.5m intervals for wind resistance.

  • Secure with Torque: 10-15 Nm; use stainless hardware.

  • Inspect: Test for alignment and weatherproofing.

Expert Insight: UV-stabilized polymers like those in TE Connectivity cleats extend life by 40% in solar farms.

Real-Life Example: Arizona solar installation with UV-resistant cleats cut maintenance 20% over five years. Read this also...How to Install UV-Resistant Outdoor Cable Cleats Properly

Where to Find Reliable Cable Cleats for Cable Tray Projects

Reliable cable cleats for cable tray projects are available from specialized suppliers.

  • Distributors: Thorne & Derrick for Ellis and Prysmian ranges.

  • Manufacturers: CMP Products for fire-rated options.

  • Online Platforms: Eaton B-Line for tray-compatible cleats.

  • Local Experts: North American Sales Company for custom solutions.

Expert Insight: Choose IEC 61914-compliant suppliers; market growth to $666M by 2032 demands quality sources. Read this also...Where to Find Reliable Cable Cleats for Cable Tray Projects

Conclusion: Key Takeaways and CTA

Fire-rated cleats are vital for fire-critical installations, enhancing safety and compliance. Key takeaways: Use in high-risk areas, select per IEC 61914, and integrate UV-resistant options outdoors. Ready to secure your project? Contact North American Sales Company for reliable fire-rated cleats—elevate your installations today!

FAQs About Fire-Rated Cleats in Electrical Installations

Q: What are fire-rated cable cleats? A: Devices securing cables during fires, using halogen-free materials for integrity.

Q: When to install fire-rated cleats? A: In tunnels, hospitals, and industrial sites per BS 5839.

Q: How do fire-rated cleats ensure safety? A: Maintain support under heat, reducing collapse risks by 30%.

Q: What standards apply to fire-rated cleats? A: BS 5839 and IEC 61914 for performance.

Q: Where to buy fire-rated cleats? A: From CMP or North American Sales Company.

Q: How to select for high-voltage? A: Match to 193 kA rating and environment.

Q: What features for industrial use? A: Corrosion resistance and short-circuit protection.

 
 
 

Recent Posts

See All

Comments